Instructions

Table Of Contents
Protocol Analysis
R&S
®
Scope Rider RTH
222User Manual 1326.1578.02 ─ 15
Source.........................................................................................................................222
Polarity........................................................................................................................ 222
Standard......................................................................................................................222
Bit rate, Predefined Bit Rates......................................................................................222
Threshold, Technology, Find Level............................................................................. 223
Source
Sets the source of the data line. All active analog channels can be used.
If option R&S RTH-B1 is installed, digital channels can also be used as source.
Remote command:
BUS:LIN:DATA:SOURce on page 469
Polarity
Defines the idle state of the bus. The idle state is the recessive state and corresponds
to a logical 1.
"Idle Low"
The bus is idle (state = 1) when the signal is low
"Idle High"
The bus is idle (state = 1) when the signal is high
Remote command:
BUS:LIN:POLarity on page 470
Standard
Selects the version of the LIN standard that is used in the DUT. The setting mainly
defines the checksum version used during decoding.
The most common version is v2.x. For mixed networks, or if the standard is unknown,
set the LIN standard to "Auto".
Remote command:
BUS:LIN:STANdard on page 470
Bit rate, Predefined Bit Rates
Sets the number of transmitted bits per second. The maximum bit rate is 20 kbit/s.
To select a bit rate from the list of predefined values, tap the "Predefined Bit Rates"
field, then select the value.
LIN (Option R&S
RTH-K3)