Instructions
Table Of Contents
- Cover
- Contents
- 1 For Your Safety
- 2 Getting Started
- 3 Waveform Setup
- 3.1 Connecting Probes
- 3.2 Vertical Setup
- 3.3 Horizontal Setup
- 3.4 Acquisition Control
- 3.5 Roll Mode
- 3.6 Trigger
- 3.6.1 General Trigger Settings
- 3.6.2 Edge Trigger
- 3.6.3 Glitch Trigger
- 3.6.4 Width Trigger
- 3.6.5 Video/TV Trigger
- 3.6.6 External Trigger (R&S RTH1002)
- 3.6.7 Pattern Trigger (R&S RTH-K19)
- 3.6.8 State Trigger (R&S RTH-K19)
- 3.6.9 Runt Trigger (R&S RTH-K19)
- 3.6.10 Slew Rate Trigger (R&S RTH-K19)
- 3.6.11 Data2Clock Trigger (R&S RTH-K19)
- 3.6.12 Serial Pattern Trigger (R&S RTH-K19)
- 3.6.13 Timeout Trigger (R&S RTH-K19)
- 3.6.14 Interval Trigger (R&S RTH-K19)
- 3.6.15 Window Trigger (R&S RTH-K19)
- 3.6.16 Protocol Trigger (R&S RTH-K1, -K2, -K3, -K9 and -K10)
- 4 Waveform Analysis
- 5 Mask Testing
- 6 Spectrum Analysis
- 6.1 FFT Mode
- 6.2 Spectrum Mode (Option R&S RTH-K18)
- 6.3 Harmonics Measurement (Option R&S RTH-K34)
- 7 Multimeter Measurements
- 8 Data Logging
- 9 Protocol Analysis
- 10 Logic Analyzer (R&S RTH-B1 MSO)
- 11 Frequency Counter (R&S RTH-K33)
- 12 Documenting Results
- 13 General Instrument Setup
- 14 Network Connections
- 15 Remote Control Commands
- 15.1 Conventions used in Command Description
- 15.2 Mode
- 15.3 Waveform Setup
- 15.3.1 Automatic Setup
- 15.3.2 Vertical Setup
- 15.3.3 Horizontal Setup
- 15.3.4 Acquisition Control
- 15.3.5 Trigger
- 15.3.5.1 General Trigger Settings
- 15.3.5.2 Edge Trigger
- 15.3.5.3 Glitch Trigger
- 15.3.5.4 Width Trigger
- 15.3.5.5 Video/TV Trigger
- 15.3.5.6 External Trigger (R&S RTH1002)
- 15.3.5.7 Pattern Trigger (R&S RTH-K19)
- 15.3.5.8 State Trigger (R&S RTH-K19)
- 15.3.5.9 Runt Trigger (R&S RTH-K19)
- 15.3.5.10 Slew Rate Trigger (R&S RTH-K19)
- 15.3.5.11 Data2Clock Trigger (R&S RTH-K19)
- 15.3.5.12 Serial Pattern Trigger (R&S RTH-K19)
- 15.3.5.13 Timeout Trigger (R&S RTH-K19)
- 15.3.5.14 Interval Trigger (R&S RTH-K19)
- 15.3.5.15 Window Trigger (R&S RTH-K19)
- 15.4 Waveform Analysis
- 15.5 Mask Testing
- 15.6 Spectrum Analysis
- 15.7 Digital Multimeter (R&S RTH1002)
- 15.8 Voltmeter (R&S RTH1004)
- 15.9 Counter Mode (R&S RTH-K33)
- 15.10 Data Logging
- 15.11 Protocol Analysis
- 15.12 Logic Analyzer (R&S RTH-B1 MSO)
- 15.13 Documenting Results
- 15.14 General Instrument Setup
- 15.15 WLAN Connection (Option R&S RTH-K200/200US)
- 15.16 User Scripting (R&S RTH-K38)
- Annex
- List of Commands
Protocol Analysis
R&S
®
Scope Rider RTH
209User Manual 1326.1578.02 ─ 15
Changing the thresholds in the bus configuration changes also the thresholds of ana-
log channels in the "Vertical" menu, or the thresholds of logic channels in the "Logic"
menu.
Remote command:
BUS:CAN:TECHnology on page 455
BUS:CAN:DATA:THReshold on page 456
BUS:SETReflevels on page 431
CHANnel<m>:THReshold:FINDlevel on page 309
CAN Standard
Selects the CAN protocol.
For decoding CAN buses, option R&S RTH-K3 is required and for CAN FD option
R&S RTH-K9.
Remote command:
BUS:CAN:FDATa:ENABle on page 457
CAN FD Standard
The setting is available in CAN FD option R&S RTH-K9.
Selects the standard of the tested CAN FD signal.
"Non-ISO"
Signals are decoded according to the Bosch CAN FD protocol.
"ISO"
Signals are decoded according to the ISO CAN FD protocol. This pro-
tocol has an additional stuff count field before the CRC sequence.
Remote command:
BUS:CAN:FDATa:PSTandard on page 457
Bit Rate, Predefined Bit Rates
Sets the number of transmitted bits per second. The maximum bit rate is 1 Mbit/s.
To select a bit rate from the list of predefined values, tap the "Predefined Bit Rates"
field, then select the value.
To set a user-defined value, double-tap the "Bit Rate" field, then enter the value and
unit using the displayed keypad. The "Predefined Bit Rates" setting is automatically set
to "User".
Remote command:
BUS:CAN:BITRate on page 455
Arbitratrion Bit Rate, Predefined Bit Rates
The setting is available in CAN FD option R&S RTH-K9.
Sets the bit rate of the arbitration phase. The maximum bit rate is 1 Mbit/s.
To select a bit rate from the list of predefined values, tap the "Predefined Bit Rates"
field, then select the value.
To set a user-defined value, double-tap the "Arbitratrion Bit Rate" field, then enter the
value and unit using the displayed keypad. The "Predefined Bit Rates" setting is auto-
matically set to "User".
Remote command:
BUS:CAN:FDATa:ABITrate on page 456
CAN and CAN FD (Options R&S
RTH-K3, R&S RTH-K9)