Instructions
Table Of Contents
- Cover
- Contents
- 1 For Your Safety
- 2 Getting Started
- 3 Waveform Setup
- 3.1 Connecting Probes
- 3.2 Vertical Setup
- 3.3 Horizontal Setup
- 3.4 Acquisition Control
- 3.5 Roll Mode
- 3.6 Trigger
- 3.6.1 General Trigger Settings
- 3.6.2 Edge Trigger
- 3.6.3 Glitch Trigger
- 3.6.4 Width Trigger
- 3.6.5 Video/TV Trigger
- 3.6.6 External Trigger (R&S RTH1002)
- 3.6.7 Pattern Trigger (R&S RTH-K19)
- 3.6.8 State Trigger (R&S RTH-K19)
- 3.6.9 Runt Trigger (R&S RTH-K19)
- 3.6.10 Slew Rate Trigger (R&S RTH-K19)
- 3.6.11 Data2Clock Trigger (R&S RTH-K19)
- 3.6.12 Serial Pattern Trigger (R&S RTH-K19)
- 3.6.13 Timeout Trigger (R&S RTH-K19)
- 3.6.14 Interval Trigger (R&S RTH-K19)
- 3.6.15 Window Trigger (R&S RTH-K19)
- 3.6.16 Protocol Trigger (R&S RTH-K1, -K2, -K3, -K9 and -K10)
- 4 Waveform Analysis
- 5 Mask Testing
- 6 Spectrum Analysis
- 6.1 FFT Mode
- 6.2 Spectrum Mode (Option R&S RTH-K18)
- 6.3 Harmonics Measurement (Option R&S RTH-K34)
- 7 Multimeter Measurements
- 8 Data Logging
- 9 Protocol Analysis
- 10 Logic Analyzer (R&S RTH-B1 MSO)
- 11 Frequency Counter (R&S RTH-K33)
- 12 Documenting Results
- 13 General Instrument Setup
- 14 Network Connections
- 15 Remote Control Commands
- 15.1 Conventions used in Command Description
- 15.2 Mode
- 15.3 Waveform Setup
- 15.3.1 Automatic Setup
- 15.3.2 Vertical Setup
- 15.3.3 Horizontal Setup
- 15.3.4 Acquisition Control
- 15.3.5 Trigger
- 15.3.5.1 General Trigger Settings
- 15.3.5.2 Edge Trigger
- 15.3.5.3 Glitch Trigger
- 15.3.5.4 Width Trigger
- 15.3.5.5 Video/TV Trigger
- 15.3.5.6 External Trigger (R&S RTH1002)
- 15.3.5.7 Pattern Trigger (R&S RTH-K19)
- 15.3.5.8 State Trigger (R&S RTH-K19)
- 15.3.5.9 Runt Trigger (R&S RTH-K19)
- 15.3.5.10 Slew Rate Trigger (R&S RTH-K19)
- 15.3.5.11 Data2Clock Trigger (R&S RTH-K19)
- 15.3.5.12 Serial Pattern Trigger (R&S RTH-K19)
- 15.3.5.13 Timeout Trigger (R&S RTH-K19)
- 15.3.5.14 Interval Trigger (R&S RTH-K19)
- 15.3.5.15 Window Trigger (R&S RTH-K19)
- 15.4 Waveform Analysis
- 15.5 Mask Testing
- 15.6 Spectrum Analysis
- 15.7 Digital Multimeter (R&S RTH1002)
- 15.8 Voltmeter (R&S RTH1004)
- 15.9 Counter Mode (R&S RTH-K33)
- 15.10 Data Logging
- 15.11 Protocol Analysis
- 15.12 Logic Analyzer (R&S RTH-B1 MSO)
- 15.13 Documenting Results
- 15.14 General Instrument Setup
- 15.15 WLAN Connection (Option R&S RTH-K200/200US)
- 15.16 User Scripting (R&S RTH-K38)
- Annex
- List of Commands
Spectrum Analysis
R&S
®
Scope Rider RTH
142User Manual 1326.1578.02 ─ 15
Display Harmonics, Max No Harmonics
Determines the number of harmonics to be displayed in the bargraph. Up to 64 har-
monics can be displayed. By decreasing the number of harmonics, the bargraph
becomes easier to analyze.
Note that this setting only affects the graphical result display. It has no effect on the
measurement results or the selection of harmonics for which results are provided dur-
ing a file export (manually or via remote command). For that purpose, see Limits.
Harmonics that were previously eliminated by the Limits setting cannot be displayed.
To restrict the number of harmonics to display, select a predefined selection, or "User"
and enter the "Max No Harmonics". All harmonics of an order smaller than or equal to
the specified value (and selected for analysis) are displayed.
Remote command:
HARMonic:DISPlay:TYPE on page 371
HARMonic:DISPlay:USER on page 372
HARMonic:RESult<m>:NOHarmonics? on page 381
Average
Determines the number of acquisitions for which the results are averaged. By default,
no averaging is performed.
Note that invalid measurements (for example due to clipping or a missing fundamental
frequency) are not considered for averaging.
To clear the results for previous acquisitions used for averaging, select Clear Results.
Remote command:
HARMonic:AVERage on page 371
6.3.5 Export Harmonic Results to File
Access: [MODE] = "Harmonic" > [FILE] > "Harmonics"
The results of a harmonic measurement can be exported similarly to a waveform (see
also Chapter 12, "Documenting Results", on page 267). The OneTouch functionality is
also available (see Chapter 12.6, "Quick Save with OneTouch", on page 279).
For details on the export file format, see Chapter 6.3.6.2, "Export File Format for Har-
monic Results", on page 144.
Harmonics Measurement (Option R&S RTH-K34)