Instructions
Table Of Contents
- Cover
- Contents
- 1 For Your Safety
- 2 Getting Started
- 3 Waveform Setup
- 3.1 Connecting Probes
- 3.2 Vertical Setup
- 3.3 Horizontal Setup
- 3.4 Acquisition Control
- 3.5 Roll Mode
- 3.6 Trigger
- 3.6.1 General Trigger Settings
- 3.6.2 Edge Trigger
- 3.6.3 Glitch Trigger
- 3.6.4 Width Trigger
- 3.6.5 Video/TV Trigger
- 3.6.6 External Trigger (R&S RTH1002)
- 3.6.7 Pattern Trigger (R&S RTH-K19)
- 3.6.8 State Trigger (R&S RTH-K19)
- 3.6.9 Runt Trigger (R&S RTH-K19)
- 3.6.10 Slew Rate Trigger (R&S RTH-K19)
- 3.6.11 Data2Clock Trigger (R&S RTH-K19)
- 3.6.12 Serial Pattern Trigger (R&S RTH-K19)
- 3.6.13 Timeout Trigger (R&S RTH-K19)
- 3.6.14 Interval Trigger (R&S RTH-K19)
- 3.6.15 Window Trigger (R&S RTH-K19)
- 3.6.16 Protocol Trigger (R&S RTH-K1, -K2, -K3, -K9 and -K10)
- 4 Waveform Analysis
- 5 Mask Testing
- 6 Spectrum Analysis
- 6.1 FFT Mode
- 6.2 Spectrum Mode (Option R&S RTH-K18)
- 6.3 Harmonics Measurement (Option R&S RTH-K34)
- 7 Multimeter Measurements
- 8 Data Logging
- 9 Protocol Analysis
- 10 Logic Analyzer (R&S RTH-B1 MSO)
- 11 Frequency Counter (R&S RTH-K33)
- 12 Documenting Results
- 13 General Instrument Setup
- 14 Network Connections
- 15 Remote Control Commands
- 15.1 Conventions used in Command Description
- 15.2 Mode
- 15.3 Waveform Setup
- 15.3.1 Automatic Setup
- 15.3.2 Vertical Setup
- 15.3.3 Horizontal Setup
- 15.3.4 Acquisition Control
- 15.3.5 Trigger
- 15.3.5.1 General Trigger Settings
- 15.3.5.2 Edge Trigger
- 15.3.5.3 Glitch Trigger
- 15.3.5.4 Width Trigger
- 15.3.5.5 Video/TV Trigger
- 15.3.5.6 External Trigger (R&S RTH1002)
- 15.3.5.7 Pattern Trigger (R&S RTH-K19)
- 15.3.5.8 State Trigger (R&S RTH-K19)
- 15.3.5.9 Runt Trigger (R&S RTH-K19)
- 15.3.5.10 Slew Rate Trigger (R&S RTH-K19)
- 15.3.5.11 Data2Clock Trigger (R&S RTH-K19)
- 15.3.5.12 Serial Pattern Trigger (R&S RTH-K19)
- 15.3.5.13 Timeout Trigger (R&S RTH-K19)
- 15.3.5.14 Interval Trigger (R&S RTH-K19)
- 15.3.5.15 Window Trigger (R&S RTH-K19)
- 15.4 Waveform Analysis
- 15.5 Mask Testing
- 15.6 Spectrum Analysis
- 15.7 Digital Multimeter (R&S RTH1002)
- 15.8 Voltmeter (R&S RTH1004)
- 15.9 Counter Mode (R&S RTH-K33)
- 15.10 Data Logging
- 15.11 Protocol Analysis
- 15.12 Logic Analyzer (R&S RTH-B1 MSO)
- 15.13 Documenting Results
- 15.14 General Instrument Setup
- 15.15 WLAN Connection (Option R&S RTH-K200/200US)
- 15.16 User Scripting (R&S RTH-K38)
- Annex
- List of Commands
Spectrum Analysis
R&S
®
Scope Rider RTH
115User Manual 1326.1578.02 ─ 15
The results of a spectrum measurement can be exported similarly to a waveform (see
also Chapter 12, "Documenting Results", on page 267). The OneTouch functionality is
also available (see Chapter 12.6, "Quick Save with OneTouch", on page 279).
File Format
Selects the format of the export file. For details on the file format, see Chapter 6.1.6,
"Export File Format for FFT Results", on page 116.
"CSV"
Comma-separated values (CSV) text file, the waveform is stored in a
table. The columns are separated by commas or another delimiter.
For each sample, one line is written. Values are listed in scientific
notation. You can convert the comma-separated text to columns.
"Compressed
CSV"
ZIP file that contains one or more CSV files. This format reduces the
file size.
Remote command:
SPECtrum:EXPort:NAME on page 370
Save Spectrum, Save Spectrum As
Save the spectrum results.
"Save"
Saves the file in the defined "Directory" using the autonaming pattern.
"Save As"
Opens a file explorer where you can select the directory and enter the
filename.
Remote command:
SPECtrum:EXPort:SAVE on page 370
Directory
Defines the directory where the spectrum files are stored. If a USB flash drive is con-
nected, the instrument stores the data to this external device by default.
Remote command:
SPECtrum:EXPort:NAME on page 370
Filename Base
Defines the first part of the filename. The complete filename pattern is:
<filename base>_<date>_<timestamp>.csv.
Remote command:
SPECtrum:EXPort:NAME on page 370
Store with Freq.
Includes the frequency values in the stored results.
Remote command:
SPECtrum:EXPort:INCXvalues on page 370
CSV Column Delimiter
Selects the column delimiter for CSV files. You need to know the delimiter when you
convert the CSV text to columns in a spreadsheet.
FFT Mode