User Manual

Modbus/SDI-12 Gateway User Manual Page 9 of 12
Last Updated: August 20, 2013
Appendices
This information is provided for advanced users only, and allows for configuration of units
without using the provided Windows software. Typical users do not need this information.
Appendix A - SDI-12 Configuration Register Map
The following register is valid for firmw3are version 5400-362-03 for the SDI-12/Modbus
Translator hardware. All configuration data is accessed via Modbus functions 3, 6, and 16 (holding
registers). The unit will respond to commands for any Modbus address for this range of registers.
Modbus Registers
Item Name
Length
Reserved
3000
Configuration Name
40
Last Modified
4
Modbus Direction
1
Modbus Address
1
Modbus Baud Rate
1
SDI Power
1
Poll Interval
1
Power Up Delay
1
Number of Commands
1
Auto sequence Option (internal use)
1
Reserved
8
Firmware Version Number
1
Firmware Revision Number
1
Reserved
37
Configuration Set (internal use, write 1 to implement newly written
configuration)
1
Command 1 Sensor Address
1
Command 1 Sensor Poll Interval
1
Command 1 First Input or Holding Register; actual register
(protocol address) is one less than this number
1
Command 1
1
Command 1 First Value
1
Command 1 # of Values
1
Command 1 CRC Option
1
Command 1 Data Format
1
Command 1 Word Order
1