Owner manual

Charging Ahead
Rogue Engineering Inc.
3860 S. Jason Street
Englewood Colorado 80110
1-800-364-0659 (Toll Free) 1-303-734-0706 (Phone)
1-303-734-0517 (Fax) www.rogue-engr.com
info@rogue-engr.com or sales@rogue-engr.com
Why Choose Rogues 12V/15Amp LVD?
Bene ts
Easy to Install
Control up to 180 Watt load directly or add a separate relay to control
even larger Loads
7 position selector switch makes it easy to choose the shut-o
voltage or always on LVD override
Disconnect voltage selections range from 9.0V to 11.5V
Uses a 15 Amp automotive style fuse for protection and easy
replacement
Applications
Idle reduction for work vehicles
O -grid solar installations
Recreational vehicles
And many other battery-powered installations
Features
Supports all 12V lead acid batteries
Conformal coated and potted for humid conditions
Disconnect voltages are every 0.5V from 9.0V to 11.5V
Self-Consumption: Battery (supply) voltage above disconnect
threshold: 2 milliamps (mA) and battery (supply) voltage below
disconnect threshold: 550 microamps (uA)
Testing and Reliability
Each LVD is fully tested and inspected, ensuring reliability.
Load+ Load-
Battery+ Battery-
Connect 12V Battery and 12V Load as shown in the illustration
above.
Turn knob to selected disconnect voltage or to “ON” for continous
operation.
Power to the Load will be disconnected when battery voltage
reaches selected voltage and
will reconnect when the battery is
charged 1 Volt higher than selected voltage.
If Load does not receive power when connected to a good battery,
check the fuse.
Note: Under no circumstances should a fuse rated over 15 Amps be
used with this device.