Owner`s manual
8
Figure 3. Bias switches and potentiometers
8) Flip the switch towards the rear of the amp thus disengaging the tube from the
meter circuit.
9) Repeat the above steps for each of the tubes in both channels.
As it is a quick operation, the tube bias should be checked on a regular basis.
TROUBLESHOOTING
Speaker Hum ā If hum can be heard from more than a few inches from the
loudspeaker, there is probably a ground loop. Try using the ālow Zā RCA jacks.
If there is still hum, flip the grounded/ungrounded switch on the rear panel to
ungrounded. If this fails to cure the hum, call customer service at Rogue Audio
for further advice.
Tube will not bias ā If the meter provides a reading but the tube will not bias, the
tube is probably bad. If no meter reading can be attained, check the fuse (1/4
Amp slow blow). If the fuse is bad, replace the fuse and then set the bias. If the
bias will not maintain itself and the fuse blows again, the tube should be
replaced.
Potentiometers
Switches
PDF Created with deskPDF PDF Writer - Trial :: http://www.docudesk.com