Owner`s manual
39
FACTORY DEFAULT
COMBINATION SETTINGS
The Rodgers 795 is shipped from the factory with default settings on combination
memories 1 and 2. Registrations on M1 and M2 can be changed, but if the original factory
default settings are desired, they can be restored by performing the following procedure:
RESTORING THE FACTORY DEFAULT COMBINATION SETTINGS:
1. Press and HOLD the memory select piston (M1, M2, M3 or M4) for approximately
five seconds. The display will show “LOCKED” or “UNLOCKED.”
2. While HOLDING the memory piston, press and HOLD the set piston an additional five
seconds. The display will read “MEMORY n FACTORY DEFAULT.”
3. Release both pistons. (Note : Each memory must be individually restored by the
following procedure above.)