Owner`s manual

24
ANTIPHONAL ON/MAIN OFF
The 795 is prepared with ANTIPHONAL ON (ANT ON)/MAIN OFF lighted pistons
which can operate an additional speaker system. An antiphonal speaker system is usually
installed at the opposite end of the building from the main organ allowing greater musical
flexibility. The ANTIPHONAL ON piston activates this additional speaker system, and the
MAIN OFF piston turns off the main organ. Note: If the MAIN OFF piston is engaged, the
ANTIPHONAL ON piston must be engaged or the organ will not sound through either
system.(It is possible for the installer to change the function of these pistons.)
PIPES
Any digital sampled rank in the Rodgers 795 may be replaced by a real wind-blown pipe
rank. Partial pipe ranks may be extended to full compass using Rodgers’ exclusive voicing
software with an existing sampled voice. Preparations for controlling real expression shutters
are already included in the organ software. Note: Please refer to the “Expression Range”
section.
Contact your authorized Rodgers representative for additional information.
PIPES OFF/ANCILLARY ON
If the Rodgers 795 is equipped with pipe ranks, certain stops will control pipe voices and
other stops will control digitally sampled voices. There are two tabs affecting the pipe stops
of all divisions simultaneously (ANC ON and PIPES OFF).
When the ANC ON tab is engaged, electronic voices play from the pipe stops. When the
PIPES OFF tab is engaged, the real wind blown pipes turn off. Note: If the PIPES OFF tab is
engaged, the ANC ON tab must also be engaged for the stop(s) to sound.
CONSOLE LAMP DIMMER
The illumination of the music rack, lighted stop tabs, and pedal lamps is adjusted by
performing the following procedure.
ADJUSTING THE CONSOLE LAMPS:
1. Press and hold the SET piston.
2. Turn the Select Knob counter clockwise (left) until the Console Display reads:
CONSOLE LAMPS
BRIGHT
3. Release SET.
4. Rotate the Alpha Dial to the desired intensity. The intensity choices are bright or
dim.