power your future℠ FORTIS UPS User Manual 525 VA 625 VA
ROCPOWER – FORTIS ‐ user manual TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS........................................................................................ 3 CHAPTER 1............................................................................................................................... 5 Front Panel Explanations............................................................................................................ 5 Rear Panel Explanations ...........................................
ROCPOWER – FORTIS ‐ user manual IMPORTANT SAFETY INSTRUCTIONS PLEASE, SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during unpacking, installation and maintenance of the UPS and batteries. Important Notices • • • • • • • • • • • • • • • • • • • To ensure safety in all applications where a UPS is hard‐wired to the electrical supply, the connections between the UPS and the electrical supply should be made by a qualified electrical contractor.
ROCPOWER – FORTIS ‐ user manual • • Servicing of batteries should be performed or supervised by persons knowledgeable about batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same number and type. CAUTION – Do NOT dispose of battery or batteries in a fire. The battery may explode. CAUTION – Do NOT open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.
ROCPOWER – FORTIS ‐ user manual CHAPTER 1 Front Panel Explanations 1 3 2 1. Line LED ( ): Green LED is steady when the utility is normal. Green LED flashes and the buzzer sounds every three (3) seconds when there is a utility failure. Green LED flashes every three (3) seconds when the UPS is in charging mode. Green LED is steady and the buzzer sounds continuously when the UPS is overloaded. 2. Check Battery LED ( ): Red LED flashes and buzzer sounds every 0.5 seconds when the UPS battery is low. 3.
ROCPOWER – FORTIS ‐ user manual 6 Rear Panel Explanations 1. 2. 3. 4. 5. 6. AC Input Backup Outlets: 3pcs NEMA5‐15R or IEC320 Computer Interface: True RS232 communication port. RJ11/RJ45 Jacks: MODEM /LAN Protection Site Wiring Fault Indicator: For 115Vac system only. AC Fuse Holder. (W/fuse) 525VA/115VAC/6A 800VA/115VAC/8A 525VA/230VAC/4A 800VA/230VAC/6.5A 625VA/115VAC/8A 625VA/230VAC/6.
ROCPOWER – FORTIS ‐ user manual CHAPTER 2 Unpacking CAUTION: Please be careful when lifting the shipping container or the UPS. These items are heavy. Improper lifting or movement may cause personal injuries or property damage. • • Take the UPS out of the packing material. Retain it for future use. Inspect the UPS for any obvious damage. If damage exits, IMMEDIATELY contact the hipper.
ROCPOWER – FORTIS ‐ user manual Storage Instruction For extended storage through moderate climate (‐15 to +30 °C / +5 to +86 °F), the batteries should be charged for 12 hours every six (6) months by plugging the UPS power cord into the wall outlet. Repeat this every three (3) months in a high temperature (+30 to +45 °C / +86 to +113 °F) environment.
ROCPOWER – FORTIS ‐ user manual CHAPTER 3 Important Notice Plug the UPS onto the wall outlet and charge the UPS for over 8 hours after initial installation. Connect the loads Connect the UPS to the AC power outlet. Then plug the loads into the output connectors on the rear of the UPS. To use the UPS as a master ON/OFF switch, make sure that all of the loads are switched ON. Caution: Do not connect a laser printer to the UPS outlets.
ROCPOWER – FORTIS ‐ user manual Connect Computer Interface Port (Optional) Connect the supplied interface cable to the 9‐pin computer interface port on the back of the UPS. Connect the other end to the computer. See software document for installation instructions. Operational Test Connect the UPS to the wall outlet. Push the Main Switch ON to see if the Green Line ( ) LED lights up. Connect your computer equipment to the UPS and then disconnect the UPS from the wall outlet.
ROCPOWER – FORTIS ‐ user manual CHAPTER 4 Replacing the Battery WARNING: Unplug the UPS from the electrical outlet BEFORE attempting to replace the battery. Note: Once the battery is disconnected, the loads are not protected from power outages. 1. 2. 3. 4. 5. 6. 7. 8. Use a Phillips‐head screwdriver to remove the two front panel screws and slide down the panel. Gently pull the battery out of the UPS. Loosen the black wire from the negative (‐) terminal and red wire from the positive (+) terminal.
ROCPOWER – FORTIS ‐ user manual 12 CHAPTER 5 Troubleshooting When the UPS malfunctions during operation, check the list below for suggested solutions. If the problem cannot be resolved, contact your sales agent for help. Situation Check Items AC power is normal but 'Line' 1. LED is not ON. 2. 3. Is the power switch ON? Is the fuse blown? Is the power cord loose? 'Line' LED flashes every second Battery voltage is too low but no output Solution 1. Press Main switch ON. 2. Change fuses w/same rating. 3.
ROCPOWER – FORTIS ‐ user manual CHAPTER 6 LIMITED WARRANTY This Limited Warranty is provided by Rocstorage, Inc. (hereinafter: Rocstor) for the Rocstor, Rocpower and Rocsecure lines of products. General Terms EXCEPT AS EXPRESSLY SET FORTH IN THIS LIMITED WARRANTY, ROCSTOR MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
ROCPOWER – FORTIS ‐ user manual This Limited Warranty is provided by Rocstor for Rocpower lines of products used in the ordinary course of your business. Descriptions, Drawings and Specifications Rocstor products will substantially conform to the descriptions, drawings and specifications published by Rocstor. However, the descriptions, drawings and specifications are not warranties of performance and not warranties of fitness for a particular purpose.
ROCPOWER – FORTIS ‐ user manual Buyer’s Obligation under the Warranty The person requesting coverage under this warranty shall prove that he or she is the original purchaser and declares that the product has not been sold, leased, bartered or otherwise changed possession. The buyer must notify Rocstor and show proof of notification through any reasonable means of communication in which there is acknowledgment of receipt. See full street address, email address and toll free phone numbers below.
ROCPOWER – FORTIS ‐ user manual THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT MAY VARY FROM STATE TO STATE OR FROM COUNTRY TO COUNTRY. YOU ARE ADVISED TO CONSULT APPLICABLE STATE OR COUNTRY LAWS FOR A FULL DETERMINATION OF YOUR RIGHTS. Limitation on the Use of Any Rocstor “Rocpower” Product The product you purchased was not designed for direct or indirect patient care and treatment.
ROCPOWER – FORTIS ‐ user manual After the first ninety (90) days, technical support for software that was either preinstalled by Rocstor on the Rocstor branded product or included with the Rocstor branded product at the time of your purchase or lease of the product is available for a fee. WARNING The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended.
ROCPOWER – FORTIS ‐ user manual Service Upgrades Rocstor offers extra coverage for your product. For information on service upgrades, visit www.Rocstor.com. Service upgrades purchased in one country are not transferable to another country. Manual – Disclaimer Revisions to this manual occur periodically. Please go to the Rocstor website, www.rocstor.com to obtain the most current version of the User Manual.
ROCPOWER – FORTIS ‐ user manual Trademarks Acknowledgements © 2008, Rocstorage, Inc; acknowledges the following trademarks for company names or products mentioned within the Rocstor site, portal pages and articles/text/manuals: Rocstor, Rocsecure and Rocpower are registered trademarks of Rocstorage, Inc. Rocwave, Rocforce, Smartroc, Rocsafe … are the trademarks of Rocstorage, Inc. "store your future", "secure your future" and “power your future” are the slogan marks of Rocstorage, Inc.
ROCPOWER – FORTIS ‐ user manual Contact Information Corporate Headquarters 8130 Remmet Avenue Canoga Park, CA 91304‐4129 Office: +1 (818) 449‐2000 Fax: +1 (818) 884‐8777 Email: info@Rocstor.com Technical Support / RMA Tel: (888) 877‐7716 (USA and Canada) Tel: +1 (818) 449‐2000 (Domestic and Internationals) Fax: +1 (818) 884‐8777 Hours: 9:00 am ‐ 5:00 pm PST Mon ‐ Fri (excluding holidays) Email: support@Rocstor.com Sales Info Hours: 8:00 am ‐ 5:00 pm PST Mon ‐ Fri (excluding holidays) Email: sales@Rocstor.
ROCPOWER – FORTIS ‐ user manual Note 21
ROCPOWER – FORTIS ‐ user manual Note 22
ROCPOWER – FORTIS ‐ user manual Note 23
ROCPOWER – FORTIS ‐ user manual www.ROCPOWER.