User manual
RAID 0 (Striping)
RAID 0 (Striping) is a performance-oriented, non-redundant data
mapping technique. It combines multiple hard drives into a single
logical unit. Instead of seeing several different hard drives, the
operating system sees only one large drive. Striping splits data
evenly across two or more disks simultaneously, dramatically
increasing performance.
Striping can be implemented in disks of differing sizes, but the storage space added to the array
by each disk is limited to the size of the smallest disk. Although Striping is an easily
implemented simple configuration, Striping should never be used for mission critical
applications. The speed of operation is excellent in comparison to other RAID modes.
In Striping mode, it is not possible to see the HDDs as more than one unit. If you
choose to insert all 4 HDDs, it will still be viewed as one single storage unit. When you
choose to insert only two HDDs, there is not limitation on the order of drive insertion or
the slot number.
In Striping mode, if one disk in the RAID System fails, all data in installed disks will be
lost.
When operating under Striping mode, it is not recommended to do HDD Hot Swap. Any
attempt to do so may result in complete loss of all data.
Always maintain a Backup of your files/data
BIGROC 5C – 4Bay RAID - 1U Rack Mount System - User Manual Page | 19