power your future℠ MAGNUS and ROCFORCE Parallel Redundancy On‐Line UPS Parallel System Installation Guide 4,500 VA 6,000 VA 8,000 VA 10,000 VA
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide Table of Contents IMPORTANT SAFETY INSTRUCTIONS .................................................... 3 CHAPTER 1 ........................................................................................... 6 Installation and Operation ........................................................................ 6 Unpacking.................................................................................................. 6 Installation Location...
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide IMPORTANT SAFETY INSTRUCTIONS PLEASE, SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during unpacking, installation and maintenance of the UPS and batteries.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide • • Servicing of batteries should be performed or supervised by persons knowledgeable about batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same number and type. CAUTION – Do NOT dispose of battery or batteries in a fire. The battery may explode. CAUTION – Do NOT open or mutilate the battery or batteries.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide Ensure that the UPS is properly grounded because slight leakage currents are produced by the EMI filter. The parallel function of the UPS can only be enabled in Normal Mode. Before parallel installation, measure the output voltage of each UPS. The tolerance should be less than 0.5VAC; otherwise consult your dealer before installation. Ensure that the RJ45 cable is tightly connected.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide CHAPTER 1 Installation and Operation Check the unit in its packing container and after removal, but before installation, for any obvious problems. Retain the packing material for future use. Unpacking CAUTION: Please be careful when lifting the shipping container or the UPS. These items are heavy. Improper lifting or movement may cause personal injuries or property damage. • • • Take the UPS out of the packing material.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide 7 Installation Location Normally, the design of the air flow of the UPS is that air flows in from the lower ventilation holes and then flows out from the upper ventilation holes as indicated in Fig. 1. Air flow out Select an installation position with at least 30 cm (12 inches) around the UPS and Battery banks to provide good ventilation as indicated in Fig. 2. Air flow in Fig. 1 Fig.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide CHAPTER 2 Installation Instructions Ensure to separately install the power wires and cables used for the input, output and battery connections.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide Battery Input Model 4.5 KVA, 6 KVA 8 KVA & 10 KVA Maximum Current 25A 40A Conductor Section AWG #10 AWG #10 Recommended Circuit Breaker installed in the input/output of the UPS shall be type “C” or “D” and their current ratings shall be as listed. Model 4.5 KVA, 6 KVA 8 KVA & 10 KVA Input 40A 60A Output 30A 50A Start‐up Operation Procedure Put the UPS in an appropriate location as specified in above.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide Arrange the power cables and wires, and the control signal wires as indicated in Fig. 6 and Fig. 7. Ensure that all the circuit breakers are set in the OFF position. For maintenance purposes, it is recommended that a MTBS box be purchased. When using either two or four UPS’s, slide the two terminal resistor switches to the ON position as indicted in Figure 6. Turn ON the utility input breaker (CB1 and CBi).
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide Your installation operation is complete. Set the two terminal resistors to the “On” positions when using two or four UPS’s. ID=2 ID=1 ID=4 ID=3 CB2 Load CBi CBo CBi CBo CBi CBo CBi CBo T1 CB1 MTBS BOX Fig.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide Be careful F1 Fig.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide CHAPTER 3 LIMITED WARRANTY This Limited Warranty is provided by Rocstorage, Inc. (hereinafter: Rocstor) for the Rocstor, Rocpower and Rocsecure lines of products. General Terms EXCEPT AS EXPRESSLY SET FORTH IN THIS LIMITED WARRANTY, ROCSTOR MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide This Limited Warranty is provided by Rocstor for Rocpower lines of products used in the ordinary course of your business. Descriptions, Drawings and Specifications Rocstor products will substantially conform to the descriptions, drawings and specifications published by Rocstor. However, the descriptions, drawings and specifications are not warranties of performance and not warranties of fitness for a particular purpose.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide Buyer’s Obligation under the Warranty The person requesting coverage under this warranty shall prove that he or she is the original purchaser and declares that the product has not been sold, leased, bartered or otherwise changed possession. The buyer must notify Rocstor and show proof of notification through any reasonable means of communication in which there is acknowledgment of receipt.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT MAY VARY FROM STATE TO STATE OR FROM COUNTRY TO COUNTRY. YOU ARE ADVISED TO CONSULT APPLICABLE STATE OR COUNTRY LAWS FOR A FULL DETERMINATION OF YOUR RIGHTS. Limitation on the Use of Any Rocstor “Rocpower” Product The product you purchased was not designed for direct or indirect patient care and treatment.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide After the first ninety (90) days, technical support for software that was either preinstalled by Rocstor on the Rocstor branded product or included with the Rocstor branded product at the time of your purchase or lease of the product is available for a fee. WARNING The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide Service Upgrades Rocstor offers extra coverage for your product. For information on service upgrades, visit www.Rocstor.com. Service upgrades purchased in one country are not transferable to another country. Manual – Disclaimer Revisions to this manual occur periodically. Please go to the Rocstor website, www.rocstor.com to obtain the most current version of the User Manual.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide Trademark Acknowledgements © 2008, Rocstorage, Inc; acknowledges the following trademarks for company names or products mentioned within the Rocstor site, portal pages and articles/text/manuals: Rocstor, Rocsecure and Rocpower are registered trademarks of Rocstorage, Inc. Rocwave, Rocforce, Smartroc, Rocsafe … are the trademarks of Rocstorage, Inc.
ROCPOWER – MAGNUS and ROCFORCE ‐ Parallel System Installation Guide Contact Information Corporate Headquarters 8130 Remmet Avenue Canoga Park, CA 91304‐4129 Office: +1 (818) 449‐2000 Fax: +1 (818) 884‐8777 Email: info@Rocstor.com Technical Support / RMA Tel: (888) 877‐7716 (USA and Canada) Tel: +1 (818) 449‐2000 (Domestic and Internationals) Fax: +1 (818) 884‐8777 Hours: 9:00 am ‐ 5:00 pm PST Mon ‐ Fri (excluding holidays) Email: support@Rocstor.