Specifications
UC864-E/G AT Commands Reference Guide
80304ST10041a Rev. 3 - 18/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 68 of 259
+CREG - Network Registration Report
+CREG: 0,1
OK
Reference 3GPP TS 27.007
3.5.4.3.4 Operator Selection - +COPS
+COPS - Operator Selection
AT+COPS=
[<mode>
[,<format>
[,<oper>>[,< AcT>]]]]
Set command forces an attempt to select and register the GSM\UMTS
network operator.
<mode> parameter defines whether the operator selection is done
automatically or it is forced by this command to operator <oper>.
The operator <oper> shall be given in format <format>.
Parameters:
<mode>
0 - automatic choice (the parameter <oper> will be ignored) (factory
default)
1 - manual choice (<oper> field shall be present)
2 - deregister from the network; the MODULE is kept unregistered until a
+COPS with <mode>=0, 1 or 4 is issued
3 - set only <format> parameter (the parameter <oper> will be ignored)
4 - manual/automatic (<oper> field shall be present); if manual selection
fails, automatic mode (<mode>=0) is entered
<format>
0 - alphanumeric long form (max length 16 digits)
1 - short format alphanumeric <oper>
2 - numeric 5 digits [country code (3) + network code (2)]
<oper>: network operator in format defined by <format> parameter.
Note: <mode> parameter setting is stored in NVM and available at next
reboot, if it is not 3 (i.e.: set only <format> parameter).
Note: if <mode>=1 or 4, the selected network is stored in NVM too and is
available at next reboot (this will happen even with a new SIM inserted)
Note: <format> parameter setting is never stored in NVM
<AcT> access technology selected:
0 GSM
2 UTRAN
AT+COPS? Read command returns current value of <mode>,<format> and <oper> in
format <format>; if no operator is selected, <format> and <oper> are
omitted
+COPS: <mode>[, <format>, <oper>],[,< AcT>]]