S25 -Delay To DTR Off
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
3.5.3.7.4 Disconnect Inactivity Timer - S30
S30 -Disconnect Inactivity Timer
ATS30=[<tout>] Set command defines the inactivity time-out in minutes. The device
disconnects if no characters are exchanged for a time period of at least
<tout> minutes.
Parameter:
<tout> - expressed in minutes
0 - disabled, disconnection due to inactivity is disabled (factory default).
1..127 - inactivity time-out value
ATS30? Read command returns the current value of S30 parameter.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
3.5.3.7.5 Delay Before Forced Hang Up - S38
S38 -Delay Before Forced Hang Up
ATS38=[<delay>] Set command sets the delay, in seconds, between the device’s receipt of H
command (or ON-to-OFF transition of DTR) and the disconnect operation.
Parameter:
<delay> - acknowledge timer in units of seconds
0..254 - the device will wait <delay> seconds for the remote device to
acknowledge all data in the device buffer before disconnecting
(factory default value is 20).
255 - the device doesn’t time-out and continues to attempt to deliver data
in the buffer until the connection is lost or the data is delivered.
Note: <delay> parameter can be used to ensure that data in device buffer is
sent before device disconnects.
ATS38? Read command returns the current value of S38 parameter.