Specifications

UC864-E/G AT Commands Reference Guide
80304ST10041a Rev. 3 - 18/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 55 of 259
3.5.3.7.5 Response Formatting Character - S4
S4 - Response Formatting Character
ATS4=[<char>] Set command sets the value of the character generated by the device as
part of the header, trailer, and terminator for result codes and information
text, along with the S3 parameter.
Parameter:
<char> - response formatting character (decimal ASCII)
0..127 - factory default value is 10 (ASCII LF)
Note: if the value of S4 is changed in a command line the result code issued
in response of that command line will use the new value of S4.
ATS4? Read command returns the current value of S4 parameter.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
Reference V25ter
3.5.3.7.6 Command Line Editing Character - S5
S5 - Command Line Editing Character
ATS5=[<char>] Set command sets the value of the character recognized by the device as a
request to delete from the command line the immediately preceding
character.
Parameter:
<char> - command line editing character (decimal ASCII)
0..127 - factory default value is 8 (ASCII BS)
ATS5? Read command returns the current value of S5 parameter.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
Reference V25ter
3.5.3.7.7 Connection Completion Time-Out - S7
S7 - Connection Completion Time-Out
ATS7=[<tout>] Set command sets the amount of time, in seconds, that the device shall
allow between either answering a call (automatically or by A command) or
completion of signalling of call addressing information to network (dialling),
and establishment of a connection with the remote device.
Parameter:
<tout> - number of seconds
1..255 - factory default value is 60
ATS7? Read command returns the current value of S7 parameter.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s