Specifications

UC864-E/G AT Commands Reference Guide
80304ST10041a Rev. 3 - 18/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 194 of 259
#AUTOBND - Automatic Band Selection
AT#AUTOBND=
[<value>]
Set command enables/disables the automatic band selection at power-on.
Parameter:
<value>:
0 - disables automatic band selection at power-on (factory default)
1 - enables automatic band selection at power-on; +COPS=0 is necessary
condition to effectively have automatic band selection at next power-on;
the automatic band selection stops as soon as a GSM cell is found.
Note: if automatic band selection is enabled the band changes every about
90 seconds through available bands until a GSM cell is found.
AT#AUTOBND? Read command returns whether the automatic band selection is enabled or
not in the form:
#AUTOBND: <value>
AT#AUTOBND=? Test command returns the range of supported values for parameter
<value>.
3.5.7.1.66 Skip Escape Sequence - #SKIPESC
#SKIPESC - Skip Escape Sequence
AT#SKIPESC=
[<mode>]
Set command enables/disables skipping the escape sequence +++ while
transmitting during a data connection.
Parameter:
<mode>
0 - doesn’t skip the escape sequence; its transmission is enabled (factory
default).
1 - skips the escape sequence; its transmission is not enabled.
Note: in case of an FTP connection, the escape sequence is not
transmitted, regardless of the command setting.
AT#SKIPESC? Read command reports whether escape sequence skipping is currently
enabled or not, in the format:
#SKIPESC: <mode>
AT#SKIPESC=? Test command reports supported range of values for parameter <mode>.