Specifications
UC864-E/G AT Commands Reference Guide
80304ST10041a Rev. 3 - 18/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 173 of 259
#AXE - AXE Pin Reading
AT#AXE=? Test command returns the OK result code.
3.5.7.1.31 Battery And Charger Status - #CBC
#CBC- Battery And Charger Status
AT#CBC Execution command returns the current Battery and Charger state in the
format:
#CBC: <ChargerState>,<BatteryVoltage>
where:
<ChargerState> - battery charger state
0 - charger not connected
1 - charger connected and charging
2 - charger connected and charge completed
<BatteryVoltage> - battery voltage in millivolt: it is the real battery voltage
only if charger is not connected; if the charger is connected this value
depends on the charger voltage.
AT#CBC=? Test command returns the OK result code.
3.5.7.1.32 GPRS Auto-Attach Property - #AUTOATT
#AUTOATT - Auto-Attach Property
AT#AUTOATT=
[<auto>]
Set command enables/disables the TE GPRS auto-attach property.
Parameter:
<auto>
0 - disables GPRS auto-attach property
1 - enables GPRS auto-attach property (factory default): after the
command #AUTOATT=1 has been issued (and at every following
startup) the terminal will automatically try to attach to the GPRS service.
AT#AUTOATT? Read command reports whether the auto-attach property is currently
enabled or not, in the format:
#AUTOATT: <auto>
AT#AUTOATT=? Test command reports available values for parameter <auto>.
3.5.7.1.33 Multislot Class Control - #MSCLASS
#MSCLASS - Multislot Class Control
AT#MSCLASS=
[<class>,
<autoattach>]
Set command sets the multislot class
Parameters: