Specifications
UC864-E/G AT Commands Reference Guide
80304ST10041a Rev. 3 - 18/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 163 of 259
#QTEMP - Query Temperature Overflow
Response format
AT#QTEMP? Read command queries the device internal temperature sensor for over
temperature and reports the result in the format:
#QTEMP: <temp>
where:
<temp> - over temperature indicator
0 - the device temperature is in the working range
1 - the device temperature is out of the working range
#QTEMP=? Test command reports supported range of values for parameter <mode>.
Note The device should not be operated out of its working temperature range,
elsewhere proper functioning of the device is not ensured.
3.5.7.1.18 Temperature Monitor - #TEMPMON
#TEMPMON - Temperature Monitor
AT#TEMPMON=
<mod>
[,<urcmode>
[,<action>
[,<hyst_time>
[,<GPIO>]]]]
Set command sets the behaviour of the module internal temperature
monitor.
Parameters:
<mod>
0 - sets the command parameters.
1 - triggers the measurement of the module internal temperature,
reporting the result in the format:
#TEMPMEAS: <level>,<value>
where:
<level> - threshold level
-2 - extreme temperature lower bound (see Note)
-1 - operating temperature lower bound (see Note)
0 - normal temperature
1 - operating temperature upper bound (see Note)
2 - extreme temperature upper bound (see Note)
<value>
actual temperature expressed in Celsius degrees
Setting of the following optional parameters has meaning only if
<mod>=0: