3.5.3.4. Mobile Equipment Control
3.5.3.4.1. Phone Activity Status - +CPAS
+CPAS - Phone Activity Status
AT+CPAS
Execution command reports the device status in the form:
+CPAS: <pas>
Where:
<pas> - phone activity status
0 - ready (device allows commands from TA/TE)
1 - unavailable (device does not allow commands from TA/TE)
2 - unknown (device is not guaranteed to respond to instructions)
3 - ringing (device is ready for commands from TA/TE, but the ringer is active)
4 - call in progress (device is ready for commands from TA/TE, but a call is in
progress)
5 - asleep (MT is unable to process commands from TA/TE because it is in a low
functionality state)
AT+CPAS=?
Test command reports the supported range of values for <pas>.
Note: although +CPAS is an execution command, 3gpp TS 27.007 requires the Test
command to be defined.
Example
ATD03282131321;
OK
AT+CPAS
+CPAS: 4 the called phone has answered to your call
OK
ATH
OK
Reference 3GPP TS 27.007
3.5.3.4.2. Set Phone Functionality - +CFUN
+CFUN - Set Phone Functionality
AT+CFUN=
[<fun>[,<rst>]]
Set command selects the level of functionality in the ME.
Parameters:
<fun> - is the power saving function mode
0 - powerdown module.
1 - mobile full functionality with power saving disabled (factory default)
4 - disable both TX and RX
5 - mobile full functionality with power saving
<rst> - reset flag
0 - do not reset the ME before setting it to <fun> functionality level
Note: For AT&T model, mode 0 and 4 have same action which is disabling both