#DBGS – Debug screen command
#DBGS:
Total time: <total_time>, 2G time: <2G_time>, 3G time: <3G_time>,
Cr2g2gCntSu: <cr_2g_2g_cnt_su>,
Cr2g2gCntAt: <cr_2g_2g_cnt_at>, IrCr2g3gCntSu: <ir_cr_2g_3g_cnt_su>,
IrCr2g3gCntAt:
<ir_cr_2g_3g_cnt_at>, IrHocc2g3gCntSu: <ir_hocc_2g_3g_cnt_su>,
IrHocc2g3gCntAt:
<ir_hocc_2g_3g_cnt_at>, Ho2g2gCntSu: <ho_2g_2g_cnt_su>, Ho2g2gCntAt:
<ho_2g_2g_cnt_at>,
Cr3g3gCntSu: <cr_3g_3g_cnt_su>, Cr3g3gCntAt: <cr_3g_3g_cnt_at>,
IrCr3g2gCntSu: <ir_cr_3g_2g_cnt_su>,
IrCr3g2gCntAt: <ir_cr_3g_2g_cnt_at>, IrHocc3g2gCntSu:
<ir_hocc_3g_2g_cnt_su>, IrHocc3g2gCntAt:
<ir_hocc_3g_2g_cnt_at>, Ho3g3gCntSu: <ho_3g_3g_cnt_su>, Ho3g3gCntAt:
<ho_3g_3g_cnt_su>.
Response syntax for page_nr 8
#DBGS:
Rssi: <rssi>, SC_RAT: <sc_rat>, SC_Band:<sc_band>, THERM_ADC:
<therm_adc>, BATT_ADC:<batt_adc>
Note : if certain parameters are not available, then “-“ is printed instead, e. g.
“NOM: -“.
where:
<MCC> - Mobile country code, range 0-999 (3 digits)
<MNC> - Mobile network code, range 0-99 (2 digits)
<LAC> - Location area code, range 0-65535 (5 digits)
<arfcn> - absolute radio frequency chanel number, range 0-1023
<RxLevFull> - Received signal strength on serving cell, measured on all slots; 0h-
3Fh; 10.5.2.20 GSM04.08
<RxLevSub> - Received signal strength on serving cell, measured on all slots; 0h-
3Fh; 10.5.2.20 GSM04.08
<RxQualFull> - Received signal quality on serving cell, measured on all slots;
range 0-7; 10.5.2.20 GSM04.08
<RxQualSub> - Received signal qual.onserving cell, measured on a subset of slots,
range 0-7;10.5.2.20 GSM04.08
<rx_acc_min> - RXLEV-ACCESS-MIN, range 0-63; 10.5.2.4 GSM04.08
<c1> - Value of c1; 6.4 GSM04.08
<c2> - Value of c2; 6.4 GSM04.08
<txpwr> - Transmit power level of the current connection, range 0-31
(5 bits); 10.5.2.4 GSM04.08
<dtx_used> - DTX used, range 0-1; 10.5.2.4 GSM04.08
<t3212> - T3212. The T3212 timeout value field is coded as the binary