Specifications

HE863 family AT commands reference guide
80377ST10083a Rev.4 – 2012-02-01
Reproduction forbidden without written authorization from Telit Communications S.p.A.- All Rights Reserved. Page 155 of
228
#SHSNR - Handset Noise Reduction
<mode>
Parameter:
<mode>
0 - disables noise reduction for handset mode (default)
1 - enables noise reduction for handset mode
Note: This parameter is saved in NVM issuing AT&W command.
AT# SHSNR?
Read command reports whether the noise reduction function on audio
handset input is currently enabled or not, in the format:
#SHSNR: <mode>
AT# SHSNR =?
Test command returns the supported range of values of parameter
<mode>.
3.5.5.1.39. Set Handset Sidetone - #SHSSD
#SHSSD - Set Handset Sidetone
AT#SHSSD=
<mode>
Set command enables/disables the sidetone on handset audio output.
Parameter:
<mode>
0 - disables the handset sidetone
1 - enables the handset sidetone (factory default)
Note: This parameter is saved in NVM issuing AT&W command.
AT#SHSSD?
Read command reports whether the headset sidetone is currently enabled or not, in
the format:
#SHSSD: <mode>
AT#SHSSD=?
Test command returns the supported range of values of parameter <mode>.
3.5.5.1.40. Network Timezone - #NITZ
#NITZ - Network Timezone
AT#NITZ=
[<val>
[,<mode>]]
Set command enables/disables (a) automatic date/time updating, (b) Full
Network Name applying and (c) #NITZ URC; moreover it permits to change
the #NITZ URC format.
Date and time information can be sent by the network after GSM
registration or after GPRS attach.
Parameters:
<val>
0 - disables (a) automatic data/time updating, (b) Full Network Name
applying and (c) #NITZ URC; moreover it sets the #NITZ URC ‘basic’
format (see <datetime> below) (factory default)
1..15 - as a sum of:
1 - enables automatic date/time updating