#VAUX- Auxiliary Voltage Output Control
0 - output off
1 - output on
2 - query current value of VAUX pin
Note: when <stat>=2 and command is successful, it returns:
#VAUX: <value>
where:
<value> - power output status
0 - output off
1 - output on(factory default)
Note: the current setting is stored through #VAUXSAV
AT#VAUX?
Read command reports whether the Auxiliary Voltage pin output is currently
enabled or not, in the format:
#VAUX: <value>
AT#VAUX=?
Test command reports the supported range of values for parameters <n>, <stat>.
3.5.5.1.19. Auxiliary Voltage Output Save - #VAUXSAV
#VAUXSAV - Auxiliary Voltage Output Save
AT#VAUXSAV
Execution command saves the actual state of #VAUX pin to NVM. The state will
be reload at power-up.
AT#VAUXSAV=?
Test command returns the OK result code.
3.5.5.1.20. AXE Pin Reading - #AXE
#AXE - AXE Pin Reading
AT#AXE
Execution command causes the ME to return the current state of AXE pin in the
format:
#AXE: <state>
where:
<state>
0 - Low
1 - High
AT#AXE=?
Test command returns the OK result code.
3.5.5.1.21. Battery And Charger Status - #CBC
#CBC- Battery And Charger Status
AT#CBC
Execution command returns the current Battery and Charger state in the format: