Specifications

HE863 family AT commands reference guide
80377ST10083a Rev.4 – 2012-02-01
Reproduction forbidden without written authorization from Telit Communications S.p.A.- All Rights Reserved. Page 145 of
228
#SERVINFO - Serving Cell Information
<UARFCN> - UMTS ARFCN of the serving cell
<dBM> - received signal strength in dBm
<NetNameAsc> - operator name, quoted string type
<NetCode> - country code and operator code, hexadecimal representation
<PSC> - Primary Synchronisation Code
<LAC> - Localization Area Code
<DRX> - Discontinuous reception cycle length
<SD> - Service Domain
0 – No Service
1 – CS Only
2 – PS Only
3 – CS & PS
<RSCP> - Received Signal Code Power in dBm
<NOM> - Network Operation Mode
..”I”
“II”
..”III”
<RAC> - Routing Area Color Code
Note 1: In HE seriese, value of <PB-ARFCN> is displayed as blank.
3.5.5.1.16. Read Analog/Digital Converter Input - #ADC
#ADC - Read Analog/Digital Converter Input
AT#ADC=
<adc>,<mode>
[,<dir>]
Execution command reads pin<adc> voltage, converted by ADC, and outputs it in
the format:
#ADC: <value>
where:
<value> - pin<adc> voltage, expressed in mV
Parameters:
<adc> - index of pin
1 - available
2 - available
3 - available
<mode> - required action
2 - query ADC value
<dir> - direction; its interpretation is currently not implemented
0 - no effect.
Note: The command returns the last valid measure.
AT#ADC?
Read command reports all pins voltage, converted by ADC, in the format:
#ADC: <value>[<CR><LF>#ADC: <value>[…]]
AT#ADC=?
Test command reports the supported range of values of the command parameters