User Manual

Using the WebPak 3000 Drive for Web Applications: The Basics
A-11
A.3.5 Frequency I/O
The following frequency input and output are programmed to support the following
functions:
Frequency In
- Configurable as the line speed reference. 250 kHz maximum
frequency.
Frequency Out
- Programmed to support the same 31 functions supplied for the
analog input.
A.4 Setup Procedures
Setting up the drive includes:
Selecting the drive attributes
Configuring the parameters
Entering the parameter values
The Application Workbook (D2-3446) provides the user with a parameter
roadmapping tool that, when completed, simplifies the input of parameter values to the
software database of the WebPak 3000.
A.4.1 Selecting Drive Attributes
The configuration of a section will require the user to select the following drive
functional attributes:
Constant or variable diameter
Field regulator type Fixed or shaped by spillover or motor field curve
Major loop type Speed, current, position, tension
Diameter calculator
Unwind or winder
Inertia compensation
Tapered or constant tension
Losses compensation
Current memory on
Digital, analog or frequency I/O
A.4.2 Configuring the Parameters
After the drive functions listed in section A.4.1 have been selected, you will need to
configure two types of parameters to complete the drive section setup procedure:
Machine section parameters, such as, line speed, roll diameter, winder core
diameter, gear ratio, roll inertia, etc.