User Manual

6-2
WebPak 3000 DC Drive Application Workbook, Version 1.1
Set
DIAMETER
UPDATE
RATE
(P.867) to specify the number of roll revolutions
between diameter updates. This is based on web thickness. Typically, thinner
webs use a higher update number.
For
variable diameter applications
(unwinds or winders),
GEAR
IN
SPEED
(P.011) is the motor speed at
TOP
LINE
SPEED
(P.020) and
EMPTY
CORE
DIAMETER
(P.830):
Set
EMPTY
CORE
DIAMETER
(P.830).
6.2 The Diameter Calculator
Six of the inputs to the diameter calculator function block are calculated by the system:
The absolute value of
SPEED
RAMP
OUTPUT
(P.199).
The absolute value of
SPD
LOOP
FEEDBACK
(P.296).
The output of the threshold function block.
A reset diameter value determined by the status of digital input
DIAMETER
SELECT
A
TP
(P.495) (terminal 59 on the I/O Expansion board) and digital input
DIAMETER
SELECT
B
TP
(P.496) (terminal 60 on the I/O Expansion board) as shown in the
following table. P.495 and P.496 can also be asserted over the network when a
network card is installed.
DIAMETER
/
TAPER
IN
TP
(P.192), which is the value in counts of the input after gain and
zero have been applied.
DIAMETER
RESET
TP
(P.829) will reset the diameter calculator to a diameter based on
the status of
DIAMETER
SELECT
A
TP
(P.495) and
DIAMETER
SELECT
B
TP
(P.496). P.829
is on when digital input 62 on the I/O Expansion board is on provided that
DIAMETER
RST
DIN
TP
(P.497) is asserted.
Range: 1 to 10
REVOLUTIONS
P.867 =
REV
Range: 1.00 to 30.00
INCHES
P.830 =
INCHES
Status
Input A
(P.495)
Status
Input B
(P.496) Reset Diameter Value
ON OFF WINDER
CORE
DIA
1 (P.822)
OFF ON WINDER
CORE
DIA
2 (P.824)
ON ON WINDER
CORE
DIA
3 (P.825)
OFF OFF UNWIND
DIAMETER
IN
(P.828) which is the analog signal of the
analog input diameter/taper (terminals 16, 17, and 18 on the
Regulator board) when
DIAMETER
/
TAPER
SELECT
(P.870) is set to
DIAMETER
.
Important:
Note that the analog signal will be maximum at
core diameter and minimum at full roll diameter.
This is consistent with the output characteristics of
a sonic roll diameter detector. When a
potentiometer is used to set diameter, the
connections should reflect maximum volts at core