User Manual

A-4
Installing and Operating the VSM500 Integrated Drive/Motor, Version 3.0
Nominal power dissipation for motor and drive combined:
Weight:
Shock:
15 G Operational, 30 G Non-Operational
Vibration:
1.0 G Operational, 2.5 G Non-Operational
Drive Protection/Fault Detection
Output overcurrent:
Trip level = 200% of max peak rated current
Output ground fault:
Trip level = 200% of max peak rated current DC bus overvoltage:
Input Voltage Unit HP Nominal Watts Loss
460 VAC 1 HP 150 W
460 VAC 2 HP 250 W
460 VAC 3 HP 350 W
460 VAC 5 HP 550 W
230 VAC 1 HP 150 W
230 VAC 2 HP 250 W
230 VAC, 1-phase 1 HP 150 W
230 VAC, 1-phase 2 HP 260 W
115 VAC, 1-phase 1 HP 180 W
Input Voltage Unit HP Weight
460 VAC 1 HP 38 lb
460 VAC 2 HP 49 lb
460 VAC 3 HP 59 lb
460 VAC 5 HP 59 lb
230 VAC 1 HP 38 lb
230 VAC 2 HP 49 lb
230 VAC, 1-phase 1 HP 38 lb
230 VAC, 1-phase 2 HP 49 lb
115 VAC, 1-phase 1 HP 38 lb
Line Voltage Trip Level
460 VAC 830 VDC
230 VAC 415 VDC
115 VAC 208 VDC