Power Cable Shielding
Power cables must be shielded, and the cable shield must connect to a g r ound.
Verify the separate brake wire shield connects to the overall chassis ground by looping back this brake
wire pair as shown in the figure Shielding of Brake Wires Within the Power Cable.
Shielding of Brake Wires Within the Power Cable
ATTENTION
High voltage can be present on the shiel ds of a power cable, if the shields ar e not
grounded.
Ver ify there is a connection t o ground for all shields in the power cable.
Failure to obse rve these safety pr ocedures cou ld result in per s onal inju ry or damage to
equipment.
Power cabl e conta ins brake wires wit h
separate ground shield.
Cable i nsulation is remove d to ex p os e
overall power cable shield.
Loop brake wires and signal shielding to contact
the overall power cable shield .
}
Factory supplied
Field Modified
Connect shi elds to powe r c able g round cl amp on drive
Clamp should contact both (o verall and br ake) cable sh ields .