User guide

Trusted
TM
Module T8449
Issue 13 Apr 10 PD-T8449 3
Table of Contents
1. Description ................................................................................................................................8
1.1. Field Termination Unit (FTU).....................................................................................................9
1.2. Field Interface Unit (FIU) ...........................................................................................................9
1.3. Host Interface Unit (HIU).........................................................................................................10
1.4. Front Panel Unit (FPU)............................................................................................................10
1.5. Line monitoring and output states ...........................................................................................11
1.6. Housekeeping .........................................................................................................................11
1.7. Fault Detection/Testing ...........................................................................................................11
1.8. Sequence of Events Characteristics .......................................................................................12
1.9. Output Switch Structure ..........................................................................................................12
1.9.1. Switch Diagnostics ..................................................................................................................14
1.9.2. Short Circuit Protection Issues ................................................................................................14
1.9.3. Group Fail Safe Switches........................................................................................................14
1.10. Control / Feedback circuits......................................................................................................14
1.11. Valve Testing...........................................................................................................................15
1.11.1. Positional Feedback ................................................................................................................15
1.11.2. Normal Operation....................................................................................................................15
1.11.3. Test Operation ........................................................................................................................16
2. Installation ...............................................................................................................................18
2.1. Module Insertion/Removal.......................................................................................................18
2.2. Field Termination Assembly (FTA) Selection..........................................................................19
2.3. Termination .............................................................................................................................19
2.4. Module Pinout Connections ....................................................................................................20
2.5. Trusted
TM
Module Polarisation/Keying. ...................................................................................21
3. Application...............................................................................................................................22
3.1. Module Configuration ..............................................................................................................22
3.2. T8449 Complex Equipment Definition.....................................................................................22
3.2.1. Rack 1: DO_TEST ..................................................................................................................24
3.2.2. Rack 2: STATE .......................................................................................................................24
3.2.3. Rack 3: AI_MXIN.....................................................................................................................26
3.2.4. Rack 4: CI_MXDAT.................................................................................................................27
3.2.5. Rack 5: MXOUT ......................................................................................................................27
3.2.6. Rack 6: ETM_EST ..................................................................................................................28
3.2.7. Rack 7: LINEFLT.....................................................................................................................29
3.2.8. Rack 8: DISCREP ...................................................................................................................29
3.2.9. Rack 9: HKEEPING ................................................................................................................30