User manual

Publication 1783-UM003D-EN-E - December 2009 135
Chapter 4
Port Status
Through RSLogix 5000 software, you can monitor port status.
In this field Values are Comments
Unit Base (for example, 1783-MS10T).
Expansion module (for example, 1783-MX08T).
Where the port resides.
Port The port number includes the port type (Fa for Fast
Ethernet and Gi for Gigabit Ethernet), the base or
expansion module number (1, 2, or 3), and the specific
port number. For example:
Gi1/1 is Gigabit Ethernet port 1 on the base.
Fa2/1 is Fast Ethernet port 1 on the first expansion
module.
The port selected for configuration.
Port Alarm Status Link fault alarm
Port not forwarding alarm
Port not operating alarm
High bit error rate alarm
No alarms
Displays the current status of the port alarm.
Link Status Active
Inactive
Displays link activity status.