Manage the Switch via the Studio 5000 Environment Chapter 5
Port Status
The Port Status tab lets you monitor alarms, statuses, thresholds, and bandwidth
utilization. As well, you can view port and cable diagnotics.
Field Description
Unit Indicates where the port resides:
Base (for example, 1783-MS10T).
Expansion module (for example, 1783-MX08T).
Port Indicates the port selected for configuration.
The port number includes the port type (Fa for Fast Ethernet and Gi for Gigabit Ethernet), the base or expansion module number (1, 2, or 3),
and the specific port number, such as in the following examples:
Gi1/1 is Gigabit Ethernet port 1 on the base.
Fa2/1 is Fast Ethernet port 1 on the first expansion module.
Port Alarm Status Displays the current status of the port alarm:
Link fault alarm
Port not forwarding alarm
Port not operating alarm
High bit error rate alarm
No alarms
Link Status Displays whether the link is active or inactive.
Port Fault Status Displays the current status of the port alarm:
Error—Disable event
SFP error—Disabled
CDP native VLAN mismatch
MAC address flap
Port security violation
No fault
Threshold Exceeded Displays unusual changes in the network traffic. If the threshold value set on the Advanced - Port Threshold tab has been exceeded, a yes value
appears in the appropriate column. If the threshold value has not been exceeded, a no value appears in the appropriate column:
Unicast—Displays a yes or no value indicating whether the current unicast traffic has exceeded the threshold value.
Multicast—Displays a yes or no value indicating whether the current multicast traffic has exceeded the threshold value.
Broadcast—Displays a yes or no value indicating whether the current broadcast traffic has exceeded the threshold value.