User Manual Version 3.0 Instruction Manual

12-8
SP600 AC Drive User Manual
Speed Ref
Cflct
Speed Ref A Sel (90) or PI Reference Sel (126) is set to
Reserved.
Under-
Voltage
The bus voltage has dropped below a predetermined
value.
User Set
Conflict
Digital Inputs on Dynamic User Sets do not match.
Datalinks on Dynamic User Sets do not match.
VHz Neg
Slope
Custom V/Hz mode has been selected in Torq Perf Mode
(53) and the V/Hz slope is negative.
Waking The wake timer is counting toward a value that will start
the drive.
Table 12.4 – Alarm Descriptions (Continued)
Alarm
Type
Description
Table 12.5 – Alarm Names Cross-Referenced by Alarm Numbers
No.
1
1
Alarm numbers not listed are reserved for future use.
Alarm No.
1
Alarm
1 Precharge Active 20 Bipolar Conflict
2 UnderVoltage 21 Motor Type Conflict
3 Power Loss 22 NP Hz Conflict
5 Analog In Loss 23 MaxFreq Conflict
6 IntDBRes OvrHeat 24 VHz Neg Slope
8 Drive OL Level 1 25 IR Volts Range
9 Drive OL Level 2 26 FluxAmps Ref Rang
10 Decel Inhibit 27 Speed Ref Cflct
11 Waking 28 Ixo Vlt Rang
17 Dig In ConflictA 29 Sleep Config
18 Dig In ConflictB 30 DigIn Bad Value
19 Dig In ConflictC 32 User Set Conflict