User Manual Version 1.0 Owner manual
Troubleshooting the Drive
13-5
13.3.1 Alarm Descriptions
Table 13.3 – Alarm Descriptions
Alarm
Type
Description
Analog In
Loss
An analog input is configured for alarm on signal loss and
signal loss has occurred.
Bipolar
Conflict
Parameter 190 (Direction Mode) is set to Bipolar or
Reverse Dis and one of more of the following digital input
functions is configured: Fwd/Rev, Run Fwd, Run Rev, Jog
Fwd, or Jog Rev.
Dig In
ConflictA
Digital input functions are in conflict. Combinations marked
with a will cause an alarm.
Dig In
ConflictB
Digital input functions are in conflict. Combinations marked
with a will cause an alarm.
Dig In
ConflictC
More than one physical input has been configured to the
same input function. Multiple configurations are not allowed
for the following input functions:
Acc2 /
Dec2
Accel 2 Decel 2 Jog Jog Fwd Jog Rev Fwd / Rev
Acc2 /
Dec2
Accel 2
Decel 2
Jog
Jog Fwd
Jog Rev
Fwd / Rev
Start Stop–CF Run Run Fwd Run Rev Jog Jog Fwd Jog Rev Fwd/Rev
Start
Stop–CF
Run
Run Fwd
Run Rev
Jog
Jog Fwd
Jog Rev
Fwd / Rev
Forward/Reverse Run Reverse Bus Regulation Mode B
Speed Select 1 Jog Forward Acc2 / Dec2
Speed Select 2 Jog Reverse Accel 2
Speed Select 3 OIM Control Decel 2
UserSetBit0 UserSetBit1