User Manual Version 1.0 Owner manual

12-62
SP600 AC Drive User Manual
Displays the present operating status of the drive.
210 Drive Status 2
Range: See figure12.31
Default: Read Only
Access: 2 Path: Utility>Diagnostics
See also: 209
Figure 12.31 – Drive Status 2 (210)
0000000x000000xx
10 01234567891112131415
1 = Condition True
0 = Condition False
x =Reserved
Bit #
Ready
Active
Running
Jogging
Stopping
DC Braking
AutoTuning
AutoRst Ctdn
AutoRst Act
Curr Limit
Bus Freq Reg
Motor Overld
DPI at 500 k
Nibble 1Nibble 2Nibble 3Nibble 4
Bit Name Description
0 Ready No start inhibits are active.
1 Active Drive is generating output voltage to the motor.
2 Running Drive is generating output voltage to the motor, run has
been selected.
3 Jogging Drive is in jog mode.
4 Stopping Drive is stopping.
5 DC Braking DC braking is active.
6 Auto Tuning Tuning function is active.
8 AutoRst Ctdn Auto Restart Countdown. Refer to parameter 174.
9 AutoRst Ac Auto Restart Active. Refer to parameter 174.
10 Curr Limit Drive is in current limit.
11 Bus Freq Reg Drive is regulating bus frequency.
12 Motor Overld Motor overload is active.
13 DPI @ 500 K DPI communications is operating at 500 kbaud (1),
125 kbaud (0)