SP600 AC Drive User Manual
Bit 0 - UserSetBit0
0 = Disabled
1 = Enabled
Bit 1 -UserSetBit1
0 = Disabled
1 =Enabled
Displays which User Set was last loaded into active memory. User
parameter changes are allowed after a User Set is restored, but will
not be detected or annunciated.
Table 12.3 – Dynamic User Set Mode
UserSetBit1 UserSetBit0 UserSet Loaded in Memory
0 0 User Set 1
0 1 User Set 2
1 0 User Set 3
1 1 User Set 3
Figure 12.29 – DynUsrSetSel
206 Dyn UserSet Actv
Range: 0 = Normal Mode (Dynamic Mode Disabled)
1 = User Set 1
2 = User Set 2
3 = User Set 3
Default: Read Only
Access: 2 Path: Utility>Drive Memory
See also: 204, 205
0xx 0xxxxxxxxxxxx
10 01234567891112131415
1 = Enabled
0 = Disabled
x =Reserved
Bit #
Factory Default Bit Values
UserSetBit0
UserSetBit1
Nibble 1Nibble 2Nibble 3Nibble 4