Input/Output Ratings
• AC line voltage (±10%): 100 - 120 VAC, single phase
200 - 240 VAC, single-phase
200 - 240 VAC, 3-phase
380 - 460 VAC, 3-phase
• AC line frequency: 47 to 63 Hz
• Maximum symmetrical RMS fault current: 100,000 A
• Horsepower: 0.5 HP to 2 HP
• Output voltage: 0 to 230 VAC or 0 to 460 VAC
• Maximum output current: 150% for 60 sec; 200% for 10 sec
• Output frequency: 0 to 240 Hz
• Output carrier frequency: 2 kHz to 8 kHz; output current is derated above 2 kHz
• Input/output current:
Control Inputs
• Rated voltage: 10 VDC to 24 VDC (±10%)
• Load (each): 10 mA minimum, 20 mA maximum
• Maximum allowable off-state leakage current: 1.5 V / 2.0 mA
• Analog input impedance: 0 to 10 V input: ≥100 kΩ
4 to 20 mA input: ~250 Ω
Relay Output
• Rated current and voltage(resistive): 0.5 A maximum at 125 VAC
1.0 A maximum at 30 VDC
Input Voltage Unit HP Input Amps Output Amps
100 -120, 1-phase 0.5
1.0
1.5
9.4
17.2
24.6
2.3
4.2
6.0
200 - 240, 1-phase 0.5
1.0
1.5
2.0
4.7
8.6
12.3
14.3
2.3
4.2
6.0
7.0
200 - 240, 3-phase 0.5
1.0
2.0
2.7
5.0
8.3
2.3
4.2
7.0
380 - 460, 3-phase 0.5
1.0
2.0
1.5
2.4
4.1
1.3
2.0
3.5