Instruction Manual
Parameters and Programming
3-11
English
Parameter
Number Parameter Name/ Description
Min./Max
Range Units
Factory
Default
Preset Frequencies (continued)
*A21 Preset Frequency 1 The programmed value sets
the frequency that the drive
outputs when selected. (Refer
to digital input settings table in
Chapter.2).
Note: If a preset frequency
input is active, the keypad
frequency pot and analog
frequency commands will be
ignored.
Note: The value of any Preset
Frequency can be changed via
F01 [
FREQUENCY COMMAND]
when the Preset Frequency is
activated via the digital inputs.
These parameters can be
changed while motor is
running.
0.0 to 360.0 0.1 Hz 0.0
*A22 Preset Frequency 2 0.0 to 360.0 0.1 Hz 3.0
*A23 Preset Frequency 3 0.0 to 360.0 0.1 Hz 5.0
*A24 Preset Frequency 4 0.0 to 360.0 0.1 Hz 10.0
*A25 Preset Frequency 5 0.0 to 360.0 0.1 Hz 15.0
*A26 Preset Frequency 6 0.0 to 360.0 0.1 Hz 20.0
*A27 Preset Frequency 7 0.0 to 360.0 0.1 Hz 25.0
*A28 Preset Frequency 8 0.0 to 360.0 0.1 Hz 30.0
*A29 Preset Frequency 9 0.0 to 360.0 0.1 Hz 35.0
*A30 Preset Frequency 10 0.0 to 360.0 0.1 Hz 40.0
*A31 Preset Frequency 11 0.0 to 360.0 0.1 Hz 45.0
*A32 Preset Frequency 12 0.0 to 360.0 0.1 Hz 50.0
*A33 Preset Frequency 13 0.0 to 360.0 0.1 Hz 55.0
*A34 Preset Frequency 14 0.0 to 360.0 0.1 Hz 60.0
*A35 Preset Frequency 15 0.0 to 360.0 0.1 Hz 0.0
*A38 Jog Frequency
This parameter sets the frequency the drive will output
when it receives a valid jog command.
This parameter can be changed while motor is running.
0.5 to 9.9 0.1Hz 5.0
A39 Jog Stop Mode
This parameter sets the stop method when the jog input
is removed.
Settings: 00=Coast
01=Ramp
02=DC Brake (See A53 [
DC WAIT TIME] –
A55 [
DC HOLD TIME])
00 to 02 Numeric
Value
01