Specifications
Publication 1747-SG001E-EN-E - February 2013
70 Select an SLC 500 Processor
specifically for the Plastics Industry and contains ERC2 algorithms forPlastics Machinery
Control.
SLC 5/05
The SLC 5/05 processor provides the same functionality as the SLC 5/04 processor with
standard Ethernet communications rather than DH+ communications. Ethernet
communication occurs at 10 Mbps or 100 Mbps, providing a high performance network
for program upload/download, online editing, and peer-to-peer messaging. Modular I/O
systems can be configured with a maximum of 3 chassis (30 total slots) and from 4 I/O
points to a maximum of 4096 I/O points.
Controller Specifications
SLC 500 Modular Controllers Specifications
Specification SLC 5/01 SLC 5/02 SLC 5/03 SLC 5/04
SLC 5/05
(3)
Catalog Number 1747- L511 L514 L524 L531 L532 L533 L541 L542 L543 L551 L552 L553
Memory Size (Words) 1 K 4 K4 K 8 K 16 K32 K16 K32 K64 K16 K32 K64 K
Backplane Current (mA)
@ 5V
90 mA 500 mA 1000 mA 1000 mA
Backplane Current (mA)
@ 24V
0 mA 175 mA
200 mA
(2)
200 mA
Digital I/O, max 7880 8192
Local chassis/slots, max. 3/30
On-board
communications
DH-485 Slave DH-485 DH-485 and RS-232 DH+ and RS-232 Ethernet and RS-232
Optional memory module EEPROM Flash EEPROM
Programming RSLogix 500
Programming Instructions 52 71 107
Typical Scan Time
(1)
8 ms/K 4.8 ms/K 1 ms/K 0.9 ms/K
Program scan hold-up
time after loss of power
20 ms…3 s (dependent on power supply loading)
Bit Execution (XIC) 4 μs2.4 μs0.44 μs0.37 μs
Clock/calendar accuracy N/A ±54 seconds/month @ 25 °C (77 °F)
±81 seconds/month @ 60 °C (140°F)
(1) The scan times are typical for a 1K ladder logic program consisting of simple ladder logic and communication servicing. Actual scan times depend on your program size,
instructions used, and the communication protocol.
(2) SLC 5/04 processors manufactured prior to April 2002 draw 200 mA @ 24V dc. Check the label to verify your processor's current draw.
(3) The 5/05 Series C processors can communicate to 100 Mbps and support increased connections: 1747-L551 = 32 connections; 1747-L552 = 48 connections; 1747-L553 = 64
connections.