Owner manual
C-2
SA500 DC Bus Supply
Induction motor Iac current values are rated at 150% overload for 1 minute.
Table C.3 – Induction Motors
Model No. HP
Max
Speed
RPM Encl
Cont Iac
RMS
Amps
Cont Idc Amps
(Bus Supply
Requirement)
Max Iac
RMS
Amps
Max Idc Amps
(Bus Supply
Requirement)
Min DC
Bus
Supply
P14A5810 1 1757 TENV 3.0 3.8 4.5 5.7
1
1. Minimum bus supply: 615055-2R or 615055-2T. Output continuous current (Idc) = 50A.
P14A5804 1.5 1756 TENV 4.4 5.5 6.6 8.3
1
P14A5813 2 1764 TENV 5.8 7.3 8.7 11.0
1
P18A6111 3 1758 TENV 9.0 11.3 13.5 17.0
1
P18A6113 5 1737 TENV 14.4 18.2 21.6 27.2
1
P21L0212 5 1781 TENV 15.3 19.3 23.0 28.9
1
P21L0213 5 1180 TENV 14.8 18.7 22.2 28.0
1
P21L0214 5 880 TENV 14.8 18.7 22.2 28.0
1
P21L0215 7.5 1780 TENV 21.5 27.1 32.3 40.7
1
P21L0216 7.5 1177 TENV 20.6 26.0 30.9 39.0
1
P21L0217 7.5 866 TEAO 21.8 27.5 32.7 41.2
1
P21L0218 10 1779 TENV 27.8 35.1 41.7 52.6
1
P21L0219 10 1171 TEAO 27.3 34.4 41.0 51.6
1
P21L0220 10 868 TEAO 28.0 35.3 42.0 53.0
1
P21L0221 15 1768 TEAO 42.0 53.0 63.0 79.4
2
2. Minimum bus supply: 615055-2S or 615055-2V. Output continuous current (Idc) = 100A.
P21L0222 15 1172 TEAO 42.0 53.0 63.0 79.4
2
P21L0223 15 872 TEAO 41.1 51.8 61.7 77.7
2