A-2
SA3100 Power Modules
Programmable Carrier Frequencies
Standard Output Voltage
Seven frame sizes (B, C, D, E, F, G, H) are available. Each frame size is line
dependent and can power a motor between the following voltages:
• 200 - 240 VAC (line dependent)
• 380 - 480 VAC (line dependent)
• 500 - 600 VAC (line dependent)
Output Current
• 2.5 - 900 A @ 620 VDC
• 2.5 - 800 A @ 775 VDC
Output Power
• 2 - 116 KVA (230V)
• 2 - 190 KVA (380V)
• 2 - 208 KVA (415V)
• 2 - 537 KVA (460V)
• 2 - 671 KVA (575V)
For information on factors that could affect the power output of the Power Module
please refer to the Enclosure and Derating Guidelines of this appendix.
Output Horsepower
• 1 - 800 HP (Continuous)
Drive HP
Rated Carrier
Frequency
Programmable Carrier
Frequency Range
1-3 4 kHz 1-12 kHz
7.5-30 4 kHz 1-12 kHz
40-60 4 kHz 1-12 kHz
75-125 2 kHz 1-6 kHz
150-250 2 kHz 1-6 kHz
300-500 2 kHz 1-4 kHz
600-650 1.5 kHz 1-4 kHz
800 1.5 kHz 1-4 kHz