Designer Instruction Manual

Publication LOGIX-UM004A-EN-P - March 2007
56 FuzzyDesigner Component Library
Parameters
Name of the component
Controller Gain parameters (P, I, D), Bias – specified by links to
components providing crisp values or by user defined constant
values
Setpoint value SP – specified by links to components providing
crisp values or by user defined constant values
Sampling period T
s
Output limiting of control variable – YES or NO
Output limits – [CV
min
, CV
max
] (if YES)
Equation format – dependent or independent gains
Derivative input format – error or process variable
Manual control (None or the link to component which defines
the manual control variable)
Mode – 0 (automatic) or 1 (manual)
Parameter b - dampens the influence of the setpoint on the
proportional action
Dead band – YES or NO
Dead Band Radius (if YES)
Dead Band Type – Zero Crossing or No Zero Crossing (if YES)
Gain forgetting factor
Output Port
The Output Port component stores an actual output value of the HFS
provided by a preceding component. The output is a crisp value.
Connections
The input link of the output port can be connected to all components
providing a crisp value, such as:
Input Port component.
Output Takagi-Sugeno Variable component.
Output Linguistic Variable component.
PID component.
Parameters
Name of the component