Step 9. To configure a RECOMM-CNET ControlNet module,
select the
CONTROLNET-MODULE
type (figure 7.10).
Click
OK
.
Step 10. Enter the
Nam
e
,
Description
and
Node
number (figure
7.11). The
Comm F
ormat
selects the communication
format for the module and must be set to
Data-INT
.
I
nput
Instance is the input connection point for the primary
connection.
O
utput
Instance is the output connection
point for the primary connection.
C
onfiguration
Instance
is the size of the configuration assembly. The values
entered will vary based on your application needs and the
size (16- or 32-bit) of the Reference/Feedback and
Datalinks in the drive. For example:
SP600 (16-Bit Ref/Fdbk and Datalinks)
Figure 7.10 – Select Module Type: Generic ControlNet Module Screen
Node configured for: Input Size Output Size
Logic Command / Reference and
Logic Status / Feedback only
42
plus Datalink A 6 4
plus Datalink B 8 6
plus Datalink C 10 8
plus Datalink D 12 10