Owner manual

6-10
ControlNet Communications Module
Figure 6.5 I/O Messaging (Continued)
007
N9:0
7
Drive
FAULTED
Status
Bit
O:000
2
Operator
Drive Faulted
Status
Display
This rung moves the Speed Reference from the operator station to the
drive.
008
MOV
Move
Source I:001
0<
Dest N10:1
0<
MOV
The rung moves the Speed Feedback from the drive to the operator
station.
009
MOV
Move
Source N9:1
0<
Dest O:001
0<
MOV
This rung moves Datalink data (N7) to the drive, where it is moved
into parameters.
010
COP
Copy File
Source #N7:0
Dest #N10:2
Length 8
COP
Drive
Datalink A1 In