5.1.1 Diamond Status Indicator
!
ATTENTION: If the serial converter is transmitting control
I/O to the product (indicated by a solid green diamond LED),
the product may fault when you remove or reset the serial
converter. Determine how your product will respond before
removing or resetting a serial converter. Failure to observe
this precaution could result bodily injury and/or damage to
equipment.
Table 5.1 – Diamond Status Indicator: State Definitions
State Cause Corrective Action
Off Serial converter is
not powered or in
Flash programming
mode.
Securely connect cables.
Apply power to the product.
Wait while Flash is in progress.
Flashing
Green
Serial converter is
operating and not
transmitting control
I/O.
No action. Removing or resetting the serial
converter will not cause a serial fault in the
product.
Solid
Green
Serial converter is
operating and is
transmitting control
I/O.
No action.
Flashing
Red
The product has
not acknowledged
the serial
converter.
Securely connect cables.
Solid
Red
Link Failure. Securely connect cables.
Replace the cable.
Cycle power to the product.
Orange Contact Reliance Electric Technical Support.