Manual
30 MP-Series Heavy Duty Electric Cylinders
Rockwell Automation Publication MPAI-IN001E-EN-P - March 2012
Commissioning
This section provides guidelines for using RSLogix™ 5000 and MotionView OnBoard software
to configure your electric cylinder servo drive system.
Required Files
Firmware revisions and software versions required to support the electric cylinders include the
following:
• RSLogix 5000 software, version 16.00 or later
• Kinetix 2000, Kinetix 6000 multi-axis drives or Ultra™ 3000 drives with SERCOS
– Firmware revision 1.96 or later
– For RSLogix 5000 software, version 16.xx,
use Motion Database file, version 4.25.0 or later
– For RSLogix 5000 software, version 17.xx or later,
use Motion Database file, version 5.18.0 or later
– For RSLogix 5000 software, version 18.xx and 19.xx,
use MPAI_5_19_11.cmf or later
• Kinetix 6200 multi-axis drives
– Firmware revision 1.30 or later
– For RSLogix 5000 software, version 17.xx,
use MPAI_5_19_11.cmf or later
• Kinetix 6500 multi-axis drives
– Firmware revision 1.11 or later
– For RSLogix 5000 software, version 18.xx,
use MPAI_5_19_11.cmf or later
• Kinetix 300 single-axis drives
– For RSLogix 5000 software, version 17.xx or later,
use Kinetix 300 drive MotionView OnBoard web interface
• Kinetix 350 single-axis Ethernet drives
– For RSLogix 5000 software, version 20.xx or later
– Firmware revision 1.30 or later
• Ultra3000 drives with Ultraware software
– Firmware revision 1.52 or later
– Motion Database (.mdb) file, dated May 2011 or later
• Motion Analyzer software, version 4.8 or later