Software Owner manual
Rockwell Automation Publication MOTION-UM004B-EN-P - October 2012 221
Understanding Your System Solution Chapter 3
3.2.2.1.2. Cut Length Analysis
When you select a Cut Length Analysis option, the following dialog box opens.
Table 132 - Cut Length Analysis Options
Parameters Description
Range Parameters
Enter the Minimum Cut Length, Maximum Cut Length, and Increment values and click Compute.
The calculated parameters are displayed in the table and Line Speed versus Cut Length chart.
Critical
Parameters
The Minimum Cut Length at Max. Line Speed and Max Line Speed values are displayed here for
reference. To adjust these values, return to the Application Template Loads
tab on page 96.
Print Print the Cut Length Analysis in a project report.