Software Owner manual
118 Rockwell Automation Publication MOTION-UM004B-EN-P - October 2012
Chapter 2 Sizing Your System
2.1.4.5. Power/Speed Templates
You can use the Power/Speed templates to enter torque and speed values that are
used to calculate the power requirements for the application.
Figure 95 - Power/Speed Templates
Table 70 - Power/Speed Template Options
Template Type Description Page
Power/Speed Template
(label 1 in Figure 95)
Use this template when the torque and speed values are known at the load
for the application.
119
Constant Power Range
Te mp lat e
(label 2 in Figure 95)
Use this template when three of the following values are known: maximum
torque, minimum torque, maximum speed, or minimum speed.
120