MinPak Plus
SingleĆPhase DĆC
Controller Description
The Reliance Electric MinPak Plus
SingleĆPhase DĆC Controller is a
fullĆwave power converter without
back rectifier, complete with an
analog current minor loop and an
analog major loop for armature
voltage or speed regulation by
tachometer feedback. The product
line has been setĆup to be sold as
listed in Table 2Ć1.
The Controller is provided, as
standard, in a NEMA Type 4/12
enclosure intended for wall or panel
mounting. It is made up of a chassis
and hinged cover. (Type 4 may be
generally defined as a washĆdown"
design. The enclosure may be
easily converted into a chassisĆonly
type configuration for panel
mounting within a large electrical
enclosure. An optical remote control
station may then be placed on the
larger enclosure's face or some
distance away.
A single power POWER ON/OFF
circuit breaker is standard with each
chassis and is independent of the
cover and faceplate.
For proper operation of the
Controller, it is necessary to use an
Operator's Station. The Operator
Stations allow the tailoring of control
functions for the application.
There are two basic configurations
that may be selected:
Local Station - station mounted
on Controller Chassis Cover
Remote Station - station
mounted remotely as a separate
unit
Local Station
Available is a selection of 8
standard Faceplates in order to
configure a controller to a specific
drive application. Refer to Table
2Ć1A. The Faceplate design
maintains the NEMA Type 4/12
rating assuming the Cover is
properly installed.
Table 2Ć1. Controller Model Numbers
Model Number
Optional
Transf.
KVA
Enclosed Chassis
HP VAC
(3)
AĆC
Amps
(RMS)
DĆC
Arm.
(Volts)
DĆC
Arm.
Amps
Avg.
DĆC
Field
Volts
Amp.
MAX
Power
Supply
Capacity
(2)
MAX MIN
14C10 14C20 1/4 115 3.5 90 2.5 100 3.0 1000 40.0 0.50
1/3 115 5.2 90 3.7 100 3.0 1000 40.0 0.75
1/2 115 7.0 90 5.0 100 3.0 1000 40.0 1.50
3/4 115 10.5 90 7.5 100 3.0 1000 40.0 1.50
14C11 14C21 1/2 230 3.5 180 2.5 200 3.0 1000 40.0 1.50
3/4 230 5.2 180 3.7 200 3.0 1000 40.0 1.50
1 230 7.0 180 5.0 200 3.0 1000 40.0 2.00
1 1/2 230 10.5 180 7.5 200 3.0 5000 40.0 3.00
14C12 14C22 2 230 14.0 180 10.0 200 3.0
1
5000 40.0 5.00
3 230 21.0 180 15.0 200 3.0
1
5000 40.0 10.0
14C13 14C23 5 230 35.0 180 25.0 200 3.0
1
5000 40.0 10.0
1
Standard
2
Maximum permissible available symmetrical RMS fault current (amperes) with NEC or CEC external approved disconnect.
3
Does not include current required for Field Supply (if used).