User Manual Instruction Manual


%" ' " % !  ""$ 
 ' $ %#$$ $$#
 $$ $"#
%!"# $ $$ $ "&  $$ #"
MAX. SPD. Fully CCW (Dot 1)
MIN. SPD Fully CCW (Dot 1)
ACC. Fully CCW (Dot 1)
DEC. Fully CCW (Dot 1)
I LIMIT 150% (Dot 7)
IR COMP Fully CCW (Dot1=0%)
Feedback
1
A
Current
Scaling
2.5
J4
2
Installed
J5, J6
3
Installed
J7, J8
4
Installed
J9
5
Installed
1> AĆCOM is the standard connection for Armature Feedback; Factory Setting.
CĆCOM is the connection for CEMF if CEMF transformer is installed;CEMF function was replaced
by Armature feedback in Design H".
TĆCOM is the connection for Tachometer Feedback if Tach Feedback Kit is installed.
2> Remove if Local Auto/Man Switch is installed.
3> Remove on 230 Volt units.
4> Remove for Torque Taper.
5> Remove when Reverse Relay (Contactor) Kit is installed.