User Manual Instruction Manual
A:3
Table AĆ2. Local Operator Control Faceplates
Specify
Operator
'
s
Functions Provided
1
When Using A
MinPak Plus
Controller With:
O
pera
t
or
'
s
Control
Faceplate
Model
Start/
Stop
SpeedĆ
setting
Pot
TorqueĆ
setting
Pot
Run/
Jog
Selector
Forward/
Reverse
Selector
Automatic/
Manual
Selector
Basic Features Plus Torque
Control and Automatic/
Manual Modes of OperaĆ
tion
14C207 yes yes yes yes no yes
Basic Features Plus ArmaĆ
tureĆReversing, Torque
Control and Automatic/
Manual Modes of OperaĆ
tion
14C208 yes yes yes yes yes yes
Table AĆ3. Remote Operator Control Stations
When Using A
MinPak Plus
Controller With:
Specify
Operator's
Station Model
Start/Stop
Rocker Switch
Speed Setting
Potentiometer
Run/Jog
Selector
Forward/
Reverse
Selector
Basic Features (Standard
Unidirectional Station)
9C45 yes yes yes no
NEMA type 4 Station with
Basic Features
9C18 yes yes yes no
ExplosionĆProof Station with
Basic Features
9C17 yes yes yes no
Basic Features Plus Armature
Reversing (Standard
Reversing Station)
9C46 yes yes yes yes
NEMA Type 4 Station for
Reversing
9C19 yes yes yes yes
ExplosionĆProof Station for
Reversing
9C16 yes yes yes yes
Table AĆ4. Isolation Transformer Specifications.
HP
kVA Primary Vac Secondary
Vac
Reliance Part
Number
1/4 0.5 230/460 115 77530Ć16A
0.5 575 115 77530Ć17A
1/3 0.75 230/460 115 77530Ć16B
0.75 575 115 77530Ć17B
1/2Ć3/4 1.5 115 115 77530Ć15D
230/460 115 77530Ć16D
575 115 77530Ć17D
230/460 230 77530Ć16D
575 230 77530Ć17D
1 2.0 230/460 230 77530Ć16E
575 230 77530Ć17E
1Ć1 1/2 3.0 230/460 230 77530Ć16F
575 230 77530Ć17F