User guide
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012 121
Upgrading the Kinetix 6000M System Firmware Appendix C
The Progress dialog box opens and upgrading begins.
After the upgrade information is sent to the IPIM module, the module
resets and performs diagnostic checking.
15. Wait for the Progress dialog box to time out.
It is normal for this process to take several minutes.
16. The Update Status dialog box opens and indicates success or failure as
described below
17. Click OK.
IMPORTANT
Do not cycle power to the drive during this process or the firmware
upgrade will not complete successfully.
Upgrading Status If
Success
1. Update complete appears in a GREEN Status dialog box.
2. Go to step 17
.
Failure
1. Update failure appears in a RED Status dialog box.
2. Refer to ControlFLASH Firmware Upgrade Kit Quick Start, publication
1756-QS105
, for troubleshooting information.